How to Reset a C448 Error Code on a Toshiba e-STUDIO 3510c

Hardware:

  • Toshiba e-STUDIO 3510c color copier
Every so often we get a fuser jam error code C448 on our Toshiba e-STUDIO 35010c copier.  Once you clear out the paper it is easy to clear the error so you can go back to copying
Step 1: Remove all the paper that is jammed in the machine.  Follow the steps on the touch screen to locate the jammed paper.
Step 2: Turn off the copier with the power rocker switch on the right side.
Main power switch location on Toshiba e-STUDIO 3510c
Step 3: Hold down the 8 and 0 on the numeric keypad while turning the machine back on.  
Once it boots up you will see the following on the touch screen:
Toshiba e-STUDIO 3510c showing D in test mode
Step 4: Enter 400 on the numeric keypad and then press the Start (copy) button.  As you type the 400 will show up in place of the D:
Step 5: Enter 0 on the numeric keypad and then press the “Enter” button on the touch screen.
Step 6: Power down the machine with the same power rocker switch as in Step 2.
Step 7: Turn on the machine with the power rocker switch.  The error should now be cleared.

Amazon Associate Disclosure: As an Amazon Associate I earn from qualifying purchases. This means if you click on an affiliate link and purchase the item, I will receive an affiliate commission. The price of the item is the same whether it is an affiliate link or not. Regardless, I only recommend products or services I believe will add value to Share Your Repair readers. By using the affiliate links, you are helping support Share Your Repair, and I genuinely appreciate your support.

Tags from the story
, , , ,
Written By
More from John Mueller
How to Enable MMS on Your Factory Unlocked iPhone 4S on Straight Talk
If you haven’t fixed your MMS settings when you switch to Straight...
Read More

2 Comments

Leave a Reply

Your email address will not be published. Required fields are marked *